Buyer Guide · FTTH

GPON ODN Materials List: What a 1:32 FTTH Build Needs

For one GPON port at a 1:32 split, the ODN (optical distribution network) needs: a patch cord and ODF port at the central office, feeder cable, one 1x32 PLC splitter or a 1x4 feeding four 1x8s, distribution cable and access boxes, up to 32 drop cables, a termination at each home and a short SC/APC patch cord to each ONT. Everything between the OLT and the ONT is passive. The split ratio fixes the counts; route lengths, box sizes and spares come from the operator design.

Published 2026-11-14 · Last reviewed 2026-11-14 · By the Lumafyn Technical Team

Bagged coils of black-jacketed fiber cable stacked on a bench in the packing area of our own factory
ISO 9001:2015ISO 14001:2015ISO 45001:2018

Lumafyn products are made at an ISO 9001 / ISO 14001 / ISO 45001 certified production base (management-system certificates issued by NOA). The certificates cover the production base, not individual products.

View certificates →

What a GPON ODN Includes

A GPON ODN is the passive fibre plant between the OLT in the central office and the ONT in the home: patch panels, cables, splices, splitters, boxes and connectors, with no powered equipment. The FOA FTTH architecture page names the parts: a feeder cable runs from the OLT to a fibre distribution hub where the splitter sits, distribution cables run toward subscribers, and drop cables make the final link to the ONT.

Diagram of one GPON PON port with a 1:32 split: OLT port, ODF with patch cord and pigtail, feeder cable, PLC splitter, FAT box, up to 32 drop cables, home termination and ONT, with counts per segment
Counts per segment for one 1:32 PON port (schematic, not a network design).

This list is written for ISPs, FTTH contractors and system integrators who need to turn a design into an order. It does not replace the operator design; it checks that nothing between the OLT and the ONT is missing from the quote.

GPON ODN Materials List per 1:32 PON Port

Multiply each row by the number of PON ports you will light; the 1:32 ratio sets the counts, and only cable lengths, box sizes and spares need the route design.

GPON ODN materials per 1:32 PON port (counts follow from the split ratio; lengths and spares from your design)
SegmentItemCount per 1:32 portWhat to specifyProduct page
Central officePatch cord, OLT port to ODF1Connector at each end (match the OLT optic datasheet and the ODF adapter), lengthSC patch cords
Central officeODF adapter + pigtail + splice position1 eachSC/APC or SC/UPC, pigtail fibre (G.652.D or G.657), TIA-598 colour orderODF panels, pigtails, adapters
FeederFeeder cable and splice closures1 routeFibre count and length from the route designDesign item
Split pointPLC splitter1 x 1x32, or 1 x 1x4 + 4 x 1x8Package (bare, ABS box, rack or LGX), input/output connectors, lead lengthsPLC splitters
DistributionDistribution cable and access boxes (FAT / NAP)Box ports totalling 32Box capacity to match the second-stage splitterDesign item; confirm separately
DropDrop cableUp to 32Flat or round, strength member, indoor/outdoor, length per surveyFTTH drop cable
Drop endsFast connectors or pre-terminated dropsUp to 64 connectors (2 per field-terminated drop)SC/APC, cable type the connector fitsFast connectors
HomeWall or termination boxUp to 32Indoor box type per operator standardDesign item
HomePatch cord to ONTUp to 32SC/APC, length, bend-insensitive fibre if routed tightlySC/APC patch cords

Counts are "up to 32" because not every splitter output is connected on day one. Order drops and ONT cords for the take-up you expect, and keep the splitter outputs for later connections.

Single 1x32 or Cascaded 1x4 + 1x8?

A single 1x32 and a 1x4 feeding four 1x8 splitters both give 32 outputs with the same theoretical split loss; the choice is about where you want the splitters and how many connection points you accept.

Single-stage vs two-stage 1:32 (theoretical loss = 10 x log10 of the split)
PointSingle 1x321x4 + four 1x8
Splitters per PON port15
Theoretical split loss15.1 dB6.0 dB + 9.0 dB = 15.1 dB
Extra connection pointsNoneOne more mated pair or splice per path
Where splitters sitOne cabinet or hubCabinet plus 4 access points
Typical reasonCentral fibre management, simple recordsLess distribution fibre in long or scattered streets

The theoretical values are 10 x log10(N); published devices add excess loss on top. Our PLC splitter ratio guide shows the maths and a worked budget for both layouts.

Check the Loss Budget Before You Order

The splitter takes most of a GPON power budget, so the material list is only final once the budget closes. The FOA PON reference gives a GPON power budget of up to 28 dB with a 32-way split.

  • A published datasheet example lists a 1x32 PLC splitter at 16.8 dB maximum insertion loss without connectors, which leaves roughly 11 dB of a 28 dB budget for fibre, connectors and splices.
  • Every extra mated connector and splice comes out of that remainder. The FOA loss budget method adds fibre, connector, splice and splitter losses for the full path.
  • If the margin is thin, reduce the ratio, move the split closer to the homes, or use higher-class optics. Values for the splitters you order are confirmed in your quotation and test records.
Technician checking an SC/APC connector end face on a video inspection scope, with green APC connector parts on the bench
End-face inspection of SC/APC parts in our own factory.

Wavelengths and Why FTTH Uses SC/APC

A GPON fibre carries 1490 nm downstream and 1310 nm upstream on the same fibre, with 1550 nm used for an RF video overlay where offered (FOA). APC connectors are polished at an 8° angle so less light reflects back toward the laser, which is why green SC/APC is the usual connector on PON patch cords, pigtails, splitters and fast connectors.

Do not mix APC and UPC on the same path: a green and a blue plug do not mate properly. The full comparison is in APC vs UPC connectors. Where the OLT optic itself has a UPC port, the OLT-to-ODF patch cord can be a hybrid with the right connector at each end.

Common Gaps in FTTH Material Lists

Most short-shipped FTTH orders miss small items that sit at the ends of the link, not the splitters or cable.

  • ONT patch cords left off. Every connected home needs one short cord, usually SC/APC.
  • Drops counted, terminations not. A field-terminated drop needs a connector at both ends; a pre-terminated drop needs the right length instead.
  • Splitter package not matched to the box. An LGX cassette will not fit an access box designed for a bare or ABS splitter.
  • Pigtail colours not stated. ODF pigtails should follow the cable colour order; see the TIA-598 color code guide.
  • No spares line. Add spare connectors, cords and a spare splitter per area according to your maintenance practice.
  • Drop lengths guessed. Use survey lengths; our FTTH drop cable buying guide covers types and lengths.

Ordering the Passive Kit from One Supplier

Sending the whole passive list in one RFQ lets the supplier check that connectors, splitters and cords match each other before anything is built. We quote patch cords, pigtails, adapters, PLC splitters, drop cable and fast connectors, with patch cord assemblies built in our own factory, and we check the list line by line before pricing. Access boxes (FAT, ODP, NAP) are listed above so the BOM is complete; ask before assuming they can be included in the same order.

Example enquiry from Southeast Asia (illustrative)
FieldExample
ProjectFTTH extension, contractor in the Philippines
PON ports8 ports, single-stage 1:32
Splitters8 x 1x32 PLC, LGX, SC/APC
DropsUp to 256, flat drop cable, lengths per survey
Cords8 OLT-to-ODF cords; ONT cords for expected take-up
Price, MOQ, lead timeConfirmed in your quotation

Data-centre links for the same operator, such as MPO trunks between core switches, can be quoted alongside; see MPO/MTP trunk cables. For the countries and project types we support in the region, see fiber optic supply for Southeast Asia, and for typical deployments see application scenarios.

FAQ

GPON ODN Materials FAQ

How many drop cables does a 1:32 PON port need?

Up to 32, one per connected home. Each splitter output can feed one ONT, so the number of drops equals the homes you connect, not the homes passed.

Is a single 1x32 splitter better than a 1x4 plus 1x8 cascade?

Neither is better in general. Both give 32 outputs with the same theoretical split loss of about 15.1 dB. The single stage keeps splitters in one place; the cascade uses more splitters and one more connection point but can save distribution fibre.

Why are FTTH connectors usually green SC/APC?

Green marks an APC connector, polished at an 8 degree angle so less light reflects back to the laser. PON systems, especially those carrying RF video at 1550 nm, use APC to keep reflections low.

Does the GPON ODN include the OLT and ONT?

No. The OLT and ONT are active equipment. The ODN is the passive part between them: patch cords, ODF, cables, splices, splitters, boxes and connectors.

What do you need to quote a GPON ODN materials list?

The number of PON ports, the split design (single 1x32 or cascaded), splitter package and connectors, drop cable type and lengths, termination method and the cords at both ends. Price, MOQ and lead time are confirmed in your quotation.

Get a Quote