GPON ODN Materials List: What a 1:32 FTTH Build Needs
For one GPON port at a 1:32 split, the ODN (optical distribution network) needs: a patch cord and ODF port at the central office, feeder cable, one 1x32 PLC splitter or a 1x4 feeding four 1x8s, distribution cable and access boxes, up to 32 drop cables, a termination at each home and a short SC/APC patch cord to each ONT. Everything between the OLT and the ONT is passive. The split ratio fixes the counts; route lengths, box sizes and spares come from the operator design.
Published 2026-11-14 · Last reviewed 2026-11-14 · By the Lumafyn Technical Team
Lumafyn products are made at an ISO 9001 / ISO 14001 / ISO 45001 certified production base (management-system certificates issued by NOA). The certificates cover the production base, not individual products.
View certificates →What a GPON ODN Includes
A GPON ODN is the passive fibre plant between the OLT in the central office and the ONT in the home: patch panels, cables, splices, splitters, boxes and connectors, with no powered equipment. The FOA FTTH architecture page names the parts: a feeder cable runs from the OLT to a fibre distribution hub where the splitter sits, distribution cables run toward subscribers, and drop cables make the final link to the ONT.

This list is written for ISPs, FTTH contractors and system integrators who need to turn a design into an order. It does not replace the operator design; it checks that nothing between the OLT and the ONT is missing from the quote.
GPON ODN Materials List per 1:32 PON Port
Multiply each row by the number of PON ports you will light; the 1:32 ratio sets the counts, and only cable lengths, box sizes and spares need the route design.
| Segment | Item | Count per 1:32 port | What to specify | Product page |
|---|---|---|---|---|
| Central office | Patch cord, OLT port to ODF | 1 | Connector at each end (match the OLT optic datasheet and the ODF adapter), length | SC patch cords |
| Central office | ODF adapter + pigtail + splice position | 1 each | SC/APC or SC/UPC, pigtail fibre (G.652.D or G.657), TIA-598 colour order | ODF panels, pigtails, adapters |
| Feeder | Feeder cable and splice closures | 1 route | Fibre count and length from the route design | Design item |
| Split point | PLC splitter | 1 x 1x32, or 1 x 1x4 + 4 x 1x8 | Package (bare, ABS box, rack or LGX), input/output connectors, lead lengths | PLC splitters |
| Distribution | Distribution cable and access boxes (FAT / NAP) | Box ports totalling 32 | Box capacity to match the second-stage splitter | Design item; confirm separately |
| Drop | Drop cable | Up to 32 | Flat or round, strength member, indoor/outdoor, length per survey | FTTH drop cable |
| Drop ends | Fast connectors or pre-terminated drops | Up to 64 connectors (2 per field-terminated drop) | SC/APC, cable type the connector fits | Fast connectors |
| Home | Wall or termination box | Up to 32 | Indoor box type per operator standard | Design item |
| Home | Patch cord to ONT | Up to 32 | SC/APC, length, bend-insensitive fibre if routed tightly | SC/APC patch cords |
Counts are "up to 32" because not every splitter output is connected on day one. Order drops and ONT cords for the take-up you expect, and keep the splitter outputs for later connections.
Single 1x32 or Cascaded 1x4 + 1x8?
A single 1x32 and a 1x4 feeding four 1x8 splitters both give 32 outputs with the same theoretical split loss; the choice is about where you want the splitters and how many connection points you accept.
| Point | Single 1x32 | 1x4 + four 1x8 |
|---|---|---|
| Splitters per PON port | 1 | 5 |
| Theoretical split loss | 15.1 dB | 6.0 dB + 9.0 dB = 15.1 dB |
| Extra connection points | None | One more mated pair or splice per path |
| Where splitters sit | One cabinet or hub | Cabinet plus 4 access points |
| Typical reason | Central fibre management, simple records | Less distribution fibre in long or scattered streets |
The theoretical values are 10 x log10(N); published devices add excess loss on top. Our PLC splitter ratio guide shows the maths and a worked budget for both layouts.
Check the Loss Budget Before You Order
The splitter takes most of a GPON power budget, so the material list is only final once the budget closes. The FOA PON reference gives a GPON power budget of up to 28 dB with a 32-way split.
- A published datasheet example lists a 1x32 PLC splitter at 16.8 dB maximum insertion loss without connectors, which leaves roughly 11 dB of a 28 dB budget for fibre, connectors and splices.
- Every extra mated connector and splice comes out of that remainder. The FOA loss budget method adds fibre, connector, splice and splitter losses for the full path.
- If the margin is thin, reduce the ratio, move the split closer to the homes, or use higher-class optics. Values for the splitters you order are confirmed in your quotation and test records.

Wavelengths and Why FTTH Uses SC/APC
A GPON fibre carries 1490 nm downstream and 1310 nm upstream on the same fibre, with 1550 nm used for an RF video overlay where offered (FOA). APC connectors are polished at an 8° angle so less light reflects back toward the laser, which is why green SC/APC is the usual connector on PON patch cords, pigtails, splitters and fast connectors.
Do not mix APC and UPC on the same path: a green and a blue plug do not mate properly. The full comparison is in APC vs UPC connectors. Where the OLT optic itself has a UPC port, the OLT-to-ODF patch cord can be a hybrid with the right connector at each end.
Common Gaps in FTTH Material Lists
Most short-shipped FTTH orders miss small items that sit at the ends of the link, not the splitters or cable.
- ONT patch cords left off. Every connected home needs one short cord, usually SC/APC.
- Drops counted, terminations not. A field-terminated drop needs a connector at both ends; a pre-terminated drop needs the right length instead.
- Splitter package not matched to the box. An LGX cassette will not fit an access box designed for a bare or ABS splitter.
- Pigtail colours not stated. ODF pigtails should follow the cable colour order; see the TIA-598 color code guide.
- No spares line. Add spare connectors, cords and a spare splitter per area according to your maintenance practice.
- Drop lengths guessed. Use survey lengths; our FTTH drop cable buying guide covers types and lengths.
Ordering the Passive Kit from One Supplier
Sending the whole passive list in one RFQ lets the supplier check that connectors, splitters and cords match each other before anything is built. We quote patch cords, pigtails, adapters, PLC splitters, drop cable and fast connectors, with patch cord assemblies built in our own factory, and we check the list line by line before pricing. Access boxes (FAT, ODP, NAP) are listed above so the BOM is complete; ask before assuming they can be included in the same order.
| Field | Example |
|---|---|
| Project | FTTH extension, contractor in the Philippines |
| PON ports | 8 ports, single-stage 1:32 |
| Splitters | 8 x 1x32 PLC, LGX, SC/APC |
| Drops | Up to 256, flat drop cable, lengths per survey |
| Cords | 8 OLT-to-ODF cords; ONT cords for expected take-up |
| Price, MOQ, lead time | Confirmed in your quotation |
Data-centre links for the same operator, such as MPO trunks between core switches, can be quoted alongside; see MPO/MTP trunk cables. For the countries and project types we support in the region, see fiber optic supply for Southeast Asia, and for typical deployments see application scenarios.
FAQ
GPON ODN Materials FAQ
How many drop cables does a 1:32 PON port need?
Up to 32, one per connected home. Each splitter output can feed one ONT, so the number of drops equals the homes you connect, not the homes passed.
Is a single 1x32 splitter better than a 1x4 plus 1x8 cascade?
Neither is better in general. Both give 32 outputs with the same theoretical split loss of about 15.1 dB. The single stage keeps splitters in one place; the cascade uses more splitters and one more connection point but can save distribution fibre.
Why are FTTH connectors usually green SC/APC?
Green marks an APC connector, polished at an 8 degree angle so less light reflects back to the laser. PON systems, especially those carrying RF video at 1550 nm, use APC to keep reflections low.
Does the GPON ODN include the OLT and ONT?
No. The OLT and ONT are active equipment. The ODN is the passive part between them: patch cords, ODF, cables, splices, splitters, boxes and connectors.
What do you need to quote a GPON ODN materials list?
The number of PON ports, the split design (single 1x32 or cascaded), splitter package and connectors, drop cable type and lengths, termination method and the cords at both ends. Price, MOQ and lead time are confirmed in your quotation.
Sources and Further Reading
- Fiber Optic Association: FTTH architectures (feeder, distribution and drop cables)
- Fiber Optic Association: FTTH PON types, wavelengths, splits and power budgets
- Fiber Optic Association: fiber optic network loss budget
- NetSource: PLC splitter guide (published insertion loss example)
- Fiber Optic Association: reflectance and APC connectors
- ITU-T G.984.2: GPON physical media dependent layer (power budget classes)
Standards and public references describe definitions and industry practice; they are not Lumafyn product data. Optical values, MOQ and lead time for your order are confirmed in your quotation and test records.