Buyer Guide · Europe

Fibre Patch Lead Colours: Jacket and Connector Colour Code for Europe

Fibre patch lead colours show the fibre type at a glance. Under TIA-598, singlemode (OS1, OS1a, OS2) leads are yellow, OM3 and OM4 are aqua, OM5 is lime green and OM1 or OM2 are orange. Many European cable makers add one difference: OM4 in Erika violet, called Heather violet in the UK. Connector bodies and boots follow a separate code: blue for singlemode UPC, green for APC and aqua for OM3/OM4. Colour is a guide, not a specification, so the jacket print and the order line still decide the fibre type.

Published 2026-11-14 · Last reviewed 2026-11-14 · By the Lumafyn Technical Team

Patch lead assembly line in our own factory with technicians terminating yellow and aqua fibre leads
ISO 9001:2015ISO 14001:2015ISO 45001:2018

Lumafyn products are made at an ISO 9001 / ISO 14001 / ISO 45001 certified production base (management-system certificates issued by NOA). The certificates cover the production base, not individual products.

View certificates →

Fibre Patch Lead Colour Chart

The fibre patch lead colour chart has two parts: the jacket colour identifies the fibre category, and the connector body or boot colour identifies the fibre and polish at the plug. The TIA-598 and connector columns come from the Fiber Optic Association colour code page; the European column uses the sheath colours and RAL numbers printed in a Prysmian distribution cable datasheet, one example of common European practice.

Fibre patch lead colour code: jacket and connector (public references, not Lumafyn product data)
Fibre typeTIA-598 jacketCommon European jacket (Prysmian example)Connector body / boot
OS1, OS1a, OS2 singlemodeYellowYellow, RAL 1018Blue (UPC); green (APC)
OM1 62.5/125OrangeGrey, RAL 7037Beige
OM2 50/125OrangeOrange, RAL 2009Black
OM3 50/125 laser-optimisedAquaAqua, RAL 6027Aqua
OM4 50/125 laser-optimisedAquaErika violet, RAL 4003Aqua; violet in some European systems
OM5 widebandLime greenLime green, RAL 6039Lime
Colour chart of fibre patch lead jackets and connectors: yellow singlemode, orange or grey OM1, orange OM2, aqua OM3, aqua or Erika violet OM4, lime green OM5, with blue, green, beige, black, aqua and lime connector colours
Jacket and connector colours side by side (schematic; on-screen colours are approximate).

Jacket Colours by Fibre Type

A jacket colour is a recommendation for indoor premises cable and cords, not a guarantee of the fibre inside. The FOA summary of TIA-598 lists yellow for singlemode, orange for OM1 and OM2, aqua for laser-optimised OM3 and OM4, and lime green for OM5. It also notes that other colours may be used if the jacket print identifies the fibre, and that outdoor cables are generally black to resist UV light (FOA).

  • Yellow means singlemode. It does not say whether the fibre is G.652.D or bend-insensitive G.657; see G.652.D vs G.657.
  • Aqua means 50/125 laser-optimised multimode, OM3 or OM4. Under TIA-598 both share the colour, so read the print.
  • Lime green is the OM5 wideband colour. Our OM4 vs OM5 guide covers when OM5 is worth specifying.
  • Orange covers older OM1 and OM2 multimode. Mixing them is the classic fault colour coding was meant to prevent.

The colours of the individual fibres inside a multi-fibre cable are a different code. That sequence (blue, orange, green, brown and so on) is explained in our TIA-598 fibre colour code guide.

Why OM4 Is Violet in Europe

OM4 is often violet in Europe because the market adopted a separate colour to stop OM4 being confused with aqua OM3. Belden explains that OM4 kept the OM3 aqua when it was approved in 2009, so the European market introduced a violet known as Heather violet in the UK and Erika violet across much of mainland Europe, and applied it to cable, adapters and connector bodies.

The colour is RAL 4003. The Prysmian datasheet lists its OM4 cable in "Erika-Violet, RAL 4003" and also shows grey (RAL 7037) for OM1, where TIA-598 uses orange. Neither choice is wrong; they are different conventions. What matters is that one site uses one convention throughout.

Aqua or Erika violet OM4: what changes
PointAqua OM4Erika violet OM4
Where it is commonTIA-598-based specifications and many cataloguesThe UK (Heather violet) and much of mainland Europe (Erika violet)
Optical performanceSame OM4 fibre categorySame OM4 fibre category
Risk on siteEasy to mix with OM3 at a panelClear split between OM3 and OM4
What to write on the order"OM4, aqua jacket""OM4, Erika violet (RAL 4003) jacket"

US-style catalogues that list an "OM4 fiber patch cord" will usually default to aqua, so a European buyer who wants violet should name the colour and the RAL number on every line.

Connector and Boot Colours

Connector colours identify the fibre and the end-face polish, and they are the quickest check before two plugs are mated. The FOA colour code page gives beige for 62.5/125, black for OM2, aqua for OM3/OM4, lime for OM5, blue for singlemode and green for singlemode APC; its connector identifier lists the same blue and green convention for TIA-568.

  • Green means APC. The 8° angled polish must never be mated with a blue UPC plug. See APC vs UPC.
  • Blue means singlemode UPC. It is the normal choice for duplex LC leads to transceivers.
  • Metal connectors (FC, ST) cannot be coloured, so the boot or strain relief carries the colour instead (FOA).
  • Violet adapters and bodies are used in some European OM4 systems to match the jacket (Belden).
Technician checking a connector end face on a video inspection scope, with a tray of green APC connector parts on the bench
End-face inspection in our own factory; the green parts in the tray are APC connector components.

What Colour Does Not Tell You

Colour does not tell you the fire rating, the bend performance, the polarity or the connector grade of a patch lead. Those items have to be written on the order line:

Items that need words, not colours
ItemWhy colour is not enoughWhere to read more
Fire performanceAn LSZH lead and a PVC lead can share a colourLSZH vs PVC jackets; CPR Euroclass
Bend-insensitive fibreG.652.D and G.657 leads are both yellowG.652.D vs G.657
Duplex polarityA-to-B and A-to-A leads look identicalA-to-B vs A-to-A
ArmourArmoured patch leads come in the same jacket coloursArmoured vs standard leads
Optical valuesInsertion and return loss are measured, not seenReading insertion and return loss results

Some sites colour leads by network instead of by fibre, for example one colour for a management network. That is allowed under the TIA-598 note quoted by the FOA, provided the jacket print still states the fibre type.

How to Write Colours on a Patch Lead Order

Write the fibre type first and the colour second, so the colour can never override the specification. A line we can quote without questions looks like this example from a UK distributor:

Example patch lead line with colours (European enquiry)
FieldExample
Connectors and polishLC/UPC to LC/UPC, duplex
FibreOM4 50/125
Jacket2.0 mm LSZH, Erika violet (RAL 4003)
Boots / connector bodiesAqua, or violet to match (state which)
PrintFibre type and your text, if required
Length and quantity3 m; quantity per line
Colour availability, MOQ for special colours, lead timeConfirmed in your quotation
  1. Fix the convention for the site. TIA aqua or European violet for OM4, grey or orange for OM1. Put it in the project specification.
  2. Name colours with a reference. "Violet" can be read as pink or purple; "Erika violet, RAL 4003" cannot.
  3. Ask for the print text. The printed legend is what an installer reads when the colour is in doubt.
  4. Check samples against the panel. Adapters and boots from different makers vary in shade.

Standard and custom colours for fibre patch leads and custom fibre patch leads are built in our own factory; the colours available for your order are confirmed in your quotation. For delivery, documents and how we work with European distributors and installers, see fibre optic supply for Europe.

FAQ

Fibre Patch Lead Colours FAQ

What colour is an OS2 fibre patch lead?

Yellow. TIA-598 uses yellow for all singlemode categories (OS1, OS1a and OS2), and European makers use the same yellow. The connector is usually blue for UPC or green for APC.

Why is my OM4 patch lead violet instead of aqua?

Because European practice often uses Erika violet (RAL 4003), called Heather violet in the UK, to separate OM4 from aqua OM3. The fibre performance is the same OM4 either way; only the colour convention differs.

What does a green connector on a patch lead mean?

Green means an APC connector with an 8 degree angled end face. Blue means UPC. The two must not be mated, because the angled and non-angled end faces do not make proper contact.

Is OM1 orange or grey?

TIA-598 lists orange for OM1 and OM2. Some European cable makers use grey for OM1, as shown in the Prysmian datasheet cited on this page. Read the jacket print to be sure.

Can I order fibre patch leads in a custom colour?

Yes, colour-coding by network or customer is common, and TIA-598 allows other colours if the jacket print identifies the fibre type. The colours we can supply for your order are confirmed in your quotation.

Get a Quote